| 数据传输速率 |
10GBASE-T / 500 MHz (Cat6A);Cat6 模式下 1 Gbps;100W PoE++ 不影响吞吐量 |
USB 3.2 Gen2 10 Gbps (兼容 Gen1 5 Gbps);可降级至 USB 2.0 HS 480 Mbps |
D 型编码:1000BASE-T(1 Gbps); A-code: 100BASE-TX (100 Mbps), 2–4 wire |
| 屏蔽 / EMC |
360° Zn-alloy shell + foil/braid STP; shield DC < 20 mΩ; coupling attenuation > 60 dB |
Full metal shell + double braid; <−35 dB near-end crosstalk @ 5 GHz; 90 Ω differential |
Shield ring + braided cable; coupling > 45 dB; D-code shielded-pair twist 12 mm |
| PoE 供电能力 |
PoE / PoE+ / PoE++ Type 4 (90–100W) at the PSE; 2.5 A per contact, ΔT < 25°C @ 2 A |
USB PD 3.0 最高 100W (20 V / 5 A) via E-marker; PPS on request; power + data simultaneous |
A-code 4P: PoE-light 1 A / 30W max; D-code not for PoE (use a separate M8 power connector) |
| 插入损耗 / 回波损耗 |
插入损耗 < 0.2 dB @ 250 MHz;回波损耗 > 18 dB @ 100 MHz、> 12 dB @ 500 MHz(符合 TIA-568.2-D) |
IL < 1.5 dB @ 5 GHz; RL > 12 dB @ 5 GHz; eye-mask pass per USB-IF compliance |
D-code: IL < 0.4 dB @ 100 MHz; RL > 16 dB; A-code contact resistance < 30 mΩ |
| 串扰(NEXT / FEXT) |
NEXT > 65 dB @ 100 MHz and > 45 dB @ 500 MHz; PSANEXT / PSAACRF compliant for 10G |
Differential NEXT < −32 dB @ 10 GHz; intra-pair skew < 8 ps |
D-code NEXT > 50 dB @ 100 MHz; pair-to-pair > 48 dB |
| 电流 / 电压 |
1.5 A per contact continuous (8P), 125 VAC / 48 VDC PoE; dielectric 1000 VAC / 60 s |
VBUS 5 A / 48 V,CC / SBU 1.25 A;耐压 500 VAC;CC 上拉 56 kΩ ±5% |
4 A / 60 V (A-code), 4 A / 50 V (D-code); proof voltage 1500 VAC |
| Sealing & temperature |
IP68 1.5 m / 2 h mated, IPX8 cable gland; −40 to +85°C; UV and salt fog 96 h |
IP67 mated, IPX5 unmated with cap; −30 to +85°C; 10,000 insertion cycles |
IP67 mated, IP65 unmated with cap; −40 to +85°C; 200 mating cycles minimum |
| Cable & field use |
22–26 AWG 实心 / 绞合线,外径 5.0–9.0 mm,免工具 IDC,可重复使用 3 次 |
Overmolded PUR / LSZH, OD 3.5–6.0 mm, screw-lock 4.5 kgf retention |
PUR / TPE, OD 4.8–6.2 mm, double shielded, 5M flex cycles |